CMCP-585A Eccentricity Monitors


Solid State Temperature Monitor

Features:

  • Low Cost

  • Small Size

  • DIN Rail Mount

  • 4-20 mA Output

  • Fault Detection

  • Buffered Transducer Output

  • Alert and Danger Alarms

  • Trip Multiply

  • Remote Reset

Approved


Description:
The CMCP585A Eccentricity Monitors are compatible with proximity probe inputs, they provide a 4-20 mA output proportional to the overall measurement. Each unit provides power for the associated transducer, processes the vibration signal to determine overall amplitude, and outputs a 4-20 mA dc current that is proportional to a user specified range such as 0-10 mils. Combining monitors with an existing PLC or DCS system results in a high density, low cost vibration monitoring system. With the alarm feature, the unit functions as a complete single channel monitor that includes alert and danger alarms, and output relays.

 

Buffered Output:
A BNC connector mounted on the front of the unit provides access to the buffered transducer output signal. This includes both the unfiltered vibration signal, and the DC bias voltage. Portable test equipment or analyzers like SKF-CM's MicrologTM can be connected to this output without disturbing other system outputs.

 

Fault Detection:
On board fault detection circuitry continuously monitors the transducer for normal operation. If a fault occurs, the output current is reduced to 2 mA to indicate the fault to the readout system. A red LED on the front of the unit is turned on to provide a local indication of the fault.

 

Alarms:
This monitoring option adds two independent set points, with LED alarm indicators and output relay contacts (Alert and Danger). Set points are adjustable via potentiometer, from 0 to 110% of full scale. Each has an adjustable delay of 1 to 10 seconds. Relay contacts can be independently configured by the user for either Normally Open (NO) (Standard) or Normally Closed (NC) operation. Relays are normally de-energized and can be configured for latching or non-latching (standard) operation. Latched alarms may be reset locally or by remote contact closure. SPST Relay contacts are rated 5 Amps @ 30 Vdc or 250 Vac for resistive loads. The Alarm option also provides set point multiplication of 3X via contact closure (2X available).

 

Displays And Assemblies:
Various display options, NEMA and explosion-proof enclosures, and assembled multi-channel systems are available. Consult your sales representative.

Monitoring Systems

 

Electrical Specifications:

  • Power: +24 Vdc @ 45 mA max. (30 mA typical at 2 full scale output). Reverse polarity and transient protection included. (With the Alarm/Relay option installed: 75 mA max.)

  • Frequency Response: 30 cpm to 300 cpm

  • Buffered Output: BNC Connector

  • Accuracy: 5.0 % of Full Scale Range.

  • Output: 4-20 mA proportional to the full scale range.

  • Maximum Load: 600 Ohms Resistive.

  • Case: Isolated.

 

Environmental Specifications:

  • Operating Temp.: -20oC to +80oC (-4oF to +176oF).

  • Storage Temp.: -55oC to +125oC (-67oF to +257oF).

  • Relative Humidity: 0 - 95% Non-Condensing.

Mounting:
32 mm (G style) or 35 mm (T style) DIN Rail.

 

Ordering Example:

To order a standard eccentricity monitor that accepts input from a 200 mV/mil proximity probe system, with a Full Scale of 0-10 mils, specify Part Number: CMCP585A-01-02.

NOTES:

1.The Full Scale option specified at order entry is used by the factory for initial calibration. However, several other ranges can be jumper selected in the field.

2.Transducer and Full Scale options not listed in the above table are available. Contact your sales representative.


Ordering Information:

Eccentricity Monitor/Transmitter CMCP585
CMCP585(X)-(aaa)-(bb)

CMCP585 Eccentricity Transmitter
CMCP585A Eccentricity Monitor

(aa) Input
01, 200 mV/mil
Specify, Specify Exact mV/mil

(bb) Full Scale
01, 0-5 mils
02, 0-10 mils

03, 0-15 mils

04, 0-20 mils

05, 0-25 mils

51, 0-125 um

52, 0-250 um

53, 0-375 um

54, 0-500 um

55, 0-625 um