The CMCP810 Runout Kit
will document electrical and mechanical runout present on a shaft. Surface
irregularities, Electrical Runout, Residual Magnetism, and Residual Stress
Concentrations can all contribute to shaft runout which will create
erroneous readings for eddy probe systems.
American Petroleum Institute (API) Standard 670 recommends that "the
combined total electrical and mechanical runout does not exceed 25 percent
of the maximum allowed peak to peak vibration amplitude or 0.25 mil (6
micrometers), whichever is greater."
The CMCP810 is the ideal tool to document these irregularities and
confirm that the shaft surface is within desired specifications for eddy
probes to observe.
|