Features
- Four Inputs
- Three Passive Outputs Per Input
- Allows Simultaneous Connection of Accelerometers, Proximity Probes and DC Powered Sensors
- BNC Buffered Output Per Channel
- Two Buffered Outputs Per Channel Available via Screw Terminal
- Onboard Constant Current Power for IEPE Sensors
- Accepts Dual Power Supplies (+ and - VDC)
- Din Rail Mountable
- Power OK Indicator
- Compact Size
The CMCP300B Four Channel Passive Buffer Module can accept four 2 or 3 wire sensors and can provide power to various accelerometers, proximity probes and speed sensors. Each channel can be independently configured to allow the use of 2 or more different sensors. Selectable constant current power is provided for all IEPE style accelerometers and dual power supply connections allow for +24V and -24V to be used simultaneously to power different sensor types. Passive Buffered Outputs are then provided via BNC, for portable instruments, and terminal blocks for hardwired systems. A total of 3 outputs are provided per input signal.